Description:
|
rptrInfoResetEvent NOTIFICATION-TYPE
OBJECTS { rptrInfoOperStatus }
STATUS current
DESCRIPTION
"In a system containing multiple managed
repeaters, the rptrInfoResetEvent notification
conveys information related to the operational
status of a repeater. This notification is sent
on completion of a repeater reset action. A
repeater reset action is defined as a transition
to the START state of Fig 9-2 in section 9 of
[IEEE 802.3 Std], when triggered by a management
command (e.g., an SNMP Set on the rptrInfoReset
object).
The agent must throttle the generation of
consecutive rptrInfoResetEvent notifications for
a single repeater so that there is at least
a five-second gap between notifications of
this type. When notifications are throttled,
they are dropped, not queued for sending at
a future time. (Note that 'generating' a
notification means sending to all configured
recipients.)
The rptrInfoResetEvent is not sent when the
agent restarts and sends an SNMP coldStart or
warmStart trap. However, it is recommended that
a repeater agent send the rptrInfoOperStatus
object as an optional object with its coldStart
and warmStart trap PDUs."
REFERENCE
"[IEEE 802.3 Mgt], 30.4.1.3.2, nRepeaterReset
notification."
|
|
|
|
Information:
|
Automatically extracted from IETF RFC 2108.
|
|
|
|