Description:
|
rptrInfoHealth NOTIFICATION-TYPE
OBJECTS { rptrInfoOperStatus }
STATUS current
DESCRIPTION
"In a system containing multiple managed repeaters,
the rptrInfoHealth notification conveys information
related to the operational status of a repeater.
It is sent either when the value of rptrInfoOperStatus
changes, or upon completion of a non-disruptive test.
The agent must throttle the generation of
consecutive rptrInfoHealth notifications for
the same repeater so that there is at least
a five-second gap between notifications of this type.
When notifications are throttled, they are dropped,
not queued for sending at a future time. (Note
that 'generating' a notification means sending
to all configured recipients.)"
REFERENCE
"[IEEE 802.3 Mgt], 30.4.1.3.1, nRepeaterHealth
notification."
|
|
|
|
Information:
|
Automatically extracted from IETF RFC 2108.
|
|
|
|