Description:
|
pimInterfaceJoinPruneInterval OBJECT-TYPE
SYNTAX Unsigned32 (0..18000)
UNITS "seconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The frequency at which this router sends PIM Join/Prune
messages on this PIM interface. This object corresponds to
the 't_periodic' timer value defined in the PIM-SM
specification. A value of zero represents an 'infinite'
interval, and indicates that periodic PIM Join/Prune
messages should not be sent on this interface."
REFERENCE "RFC 4601 section 4.11"
DEFVAL { 60 }
|
|
Information:
|
Automatically extracted from IETF RFC 5060.
|
|