Description:
|
xdsl2LConfProfRaUsTimeDs OBJECT-TYPE
SYNTAX Unsigned32(0..16383)
UNITS "seconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The Downstream Up-Shift Time Interval, to be used when
xdsl2LConfProfRaModeDs is set to 'dynamicRa'. The interval of
time that the downstream noise margin should stay above the
Downstream Up-Shift Noise Margin before the xTU-R shall attempt
to increase the downstream net data rate. The time interval
ranges from 0 to 16383 seconds."
REFERENCE "ITU-T G.997.1, paragraph #7.3.1.4.5 (RA-UTIMEds)"
DEFVAL { 3600 }
|
|
Information:
|
Automatically extracted from IETF RFC 5650.
|
|