Description:
|
xdsl2SCStatusSnrMtime OBJECT-TYPE
SYNTAX Unsigned32 (1..65535)
UNITS "symbols"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter contains the number of symbols used to measure
the SNR(f) values. It is an unsigned integer in the range from 1
to 2^16-1. After a loop diagnostic procedure, this parameter
shall contain the number of symbols used to measure the SNR(f).
It should correspond to the value specified in the Recommendation
(e.g., the number of symbols in 1 s time interval for ITU-T
Recommendation G.992.3)."
REFERENCE "ITU-T G.997.1, paragraph #7.5.1.28.1 (SNRMTds)
and paragraph #7.5.1.28.4 (SNRMTus)"
|
|
|
Information:
|
Automatically extracted from IETF RFC 5650.
|
|