Description:
|
pwOwner OBJECT-TYPE
SYNTAX INTEGER {
manual (1),
pwIdFecSignaling (2), -- PW signaling with PW ID FEC
genFecSignaling (3), -- Generalized attachment FEC
l2tpControlProtocol (4),
other (5)}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is set by the operator to indicate the protocol responsible for establishing this PW.
'manual' is used in all cases where no maintenance protocol (PW signaling) is used to set up the PW, i.e., configuration of entries in the PW tables including PW labels, etc., is done by setting the MIB fields manually.
'pwIdFecSignaling' is used in case of signaling with the Pwid FEC element with LDP signaling.
'genFecSignaling' is used in case of LDP signaling with the generalized FEC element.
'l2tpControlProtocol' indicates the use of the L2TP control protocol.
'other' is used for other types of signaling."
|
|
|
|
|
|
|
|