Description:
|
adsl2LConfProfRaDsTimeDs OBJECT-TYPE
SYNTAX Unsigned32(0..16383)
UNITS "seconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The Downstream Down-Shift Time Interval, to be used when
adsl2LConfProfRaModeDs is set to dynamicRa. The interval of
time the downstream noise margin should stay below the
Downstream Down-Shift Noise Margin before the ATU-R shall
attempt to decrease the downstream net data rate. The time
interval ranges from 0 to 16383 seconds."
REFERENCE "ITU-T G.997.1, paragraph 7.3.1.4.9"
DEFVAL { 3600 }
|
|
|
|
Information:
|