Main page
OID Repository
https://oid-base.com
Display OID:

{iso(1) identified-organization(3) dod(6) internet(1) mgmt(2) mib-2(1) transmission(10) mplsStdMIB(166) mplsLdpStdMIB(4) mplsLdpObjects(1) mplsLdpEntityObjects(2) mplsLdpEntityTable(3) mplsLdpEntityEntry(1) mplsLdpEntityMaxPduLength(8)}

mplsLdpEntityMaxPduLength(8)

 
 

OID description



   
OID: (ASN.1 notation)
(dot notation)
(OID-IRI notation)

Description:

mplsLdpEntityMaxPduLength OBJECT-TYPE
SYNTAX Unsigned32 (256..65535)
UNITS "octets"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The maximum PDU Length that is sent in
the Common Session Parameters of an Initialization
Message. According to the LDP Specification [RFC3036]
a value of 255 or less specifies the
default maximum length of 4096 octets, this is why
the value of this object starts at 256. The operator
should explicitly choose the default value (i.e., 4096),
or some other value.
The receiving LSR MUST calculate the maximum PDU
length for the session by using the smaller of its and
its peer's proposals for Max PDU Length."
REFERENCE
"RFC3036, LDP Specification, Section 3.5.3.
Initialization Message."
DEFVAL {4096}



Information:

Automatically extracted from IETF RFC 3815.

 
 
Short link:


Parent OID: mplsLdpEntityEntry(1) First sibling OID: mplsLdpEntityLdpId(1) Previous sibling OID: mplsLdpEntityUdpDscPort(7) Next sibling OID: mplsLdpEntityKeepAliveHoldTimer(9) Last sibling OID: mplsLdpEntityRowStatus(23)