Description:
|
ieee8021AsV3PathTraceDSEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value is TRUE.
NOTE: This member is included for compatibility with
IEEE Std 1588. In IEEE Std 1588, the path trace mechanism
is optional, and the pathTraceDS.enable member is
configurable (its value in IEEE Std 1588 is TRUE (1) or
FALSE (2), depending on whether the path trace mechanism is
operational or not operational, respectively. However, the
pathTrace mechanism is mandatory in this standard, and the
value of enable is always TRUE (1)."
REFERENCE
"14.6.3"
|
|
|
|