Description:
|
ieee8021AsV3PortDSCurrentOneStepTxOper OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value is TRUE (1) if it is desired, either via
management or via a received Signaling message, that the
PTP Port transmit one-step Sync messages. The value is
FALSE (2) if it is not desired, either via management or via
a received Signaling message, that the PTP Port transmit
one-step Sync messages.
NOTE: The PTP Port will send one-step Sync messages only if
currentOneStepTxOper and oneStepTransmit are both TRUE (1)."
REFERENCE
"14.10.50"
|
|