Description:
|
ieee8021AsV3PortDSUseMgtSettableLogPdelayReqInterval OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The managed object is a Boolean that determines the source
of the mean time interval between successive Pdelay_Req
messages. If the value is TRUE (1), the value of
currentLogPdelayReqInterval is set equal to the value of
mgtSettableLogPdelayReqInterval. If the value of the managed
object is FALSE (2), the value of currentLogPdelayReqInterval
is determined by the LinkDelayIntervalSetting state machine.
The default value of useMgtSettableLogPdelayReqInterval is
FALSE (2)."
REFERENCE
"14.10.26"
DEFVAL {false}
|
|