Description:
|
ieee8021XNidUnauthAllowed OBJECT-TYPE
SYNTAX INTEGER {never(1), immediate(2), authFail(3)}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Determines when the Logon Process will tell the CP state
machine to provide unauthenticated connectivity, and takes one
of the following values:
'never' : Never.
'immediate' : Immediately, independently of any current or
future attempts to authenticate using the PAE or MKA.
'authFail' : Not until an attempt has been made to
authenticate using EAP, unless neither the Supplicant nor
the Authenticator is enabled, and MKA has attempted to use
any cached CAK (unless the KaY is not enabled)."
REFERENCE
"802.1X Clause 12.5, Figure 12-3"
|
|
|
|
|
|
|
|