oid: "1.3.6.1.4.1.9.9.294.1.1.20"
short-description: "zoneMergeFailRecoverSpinLock OBJECT-TYPE"
last-modified: "2023-09-04"
parent-oid: "1.3.6.1.4.1.9.9.294.1.1"
---

## OID: `1.3.6.1.4.1.9.9.294.1.1.20`

```asn1
{iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) 9 ciscoMgmt(9) ciscoZsMIB(294) ciscoZoningMIBObjects(1) zoneConfiguration(1) zoneMergeFailRecoverSpinLock(20)}
```

### Description

```asn1
zoneMergeFailRecoverSpinLock OBJECT-TYPE
SYNTAX TestAndIncr
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to facilitate modification
of zoneMergeFailRecoverInterface,
zoneMergeFailRecoverVsan and
zoneMergeFailRecoverOper by multiple managers.
The procedure for modifying these objects is
as follows:
1. Determine new values for
zoneMergeFailRecoverInterface, zoneMergeFail-
RecoverVsan and zoneMergeFailRecoverOper.
2. Retrieve the value of zoneMergeFailRecoverSpinLock.
3. Set the value of zoneMergeFailRecoverSpinLock to
the retrieved value, and (in the same PDU) the value
of zoneMergeFailRecoverInterface to the new
value. If the set fails for
zoneMergeFailRecoverSpinLock object, go back to step
2\.
4. Set the value of zoneMergeFailRecoverSpinLock to
the retrieved value plus one, and (in the same PDU)
the value of zoneMergeFailRecoverVsan to the new
value. If the set fails for
zoneMergeFailRecoverSpinLock object, go back to step
2\.
5. Set the value of zoneMergeFailRecoverSpinLock to
the retrieved value plus two, and (in the same PDU)
the value of zoneMergeFailRecoverOper to the new
value. If the set fails for
zoneMergeFailRecoverSpinLock object, go back to step
2\.
Note that if it's possible to include
zoneMergeFailRecoverVsan and/or
zoneMergeFailRecoverOper in the (Set Req) PDU
of an earlier step, then steps 4 and/or 5 can
be eliminated."
```

**Classification:** MIB object for network management

### Child OIDs

No child OID

### Terms of Use

[Terms of use](https://oid-base.com/disclaimer.htm.md)

**Note to implementers:**: The OID repository is constantly updated but does not necessarily store the latest (or most accurate) version of this formal description. For an implementation, it is recommended to search the web for a more recent description. If this is the case, please update the above description.