oid: "1.3.6.1.4.1.762.2.1.12"
short-description: "kbControlTemperature OBJECT-TYPE"
last-modified: "2019-03-29"
parent-oid: "1.3.6.1.4.1.762.2.1"
---

## OID: `1.3.6.1.4.1.762.2.1.12`

```asn1
{iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) 762 kbridge-mib(2) karlNetKBControl(1) kbControlTemperature(12)}
```

### Description

```asn1
kbControlTemperature OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"For KarlBridges equipped with a Dallas temperature chip, returns the temperature
of the Dallas chip in 1/2 degree centigrade increments (+/- 0.5 degrees C).
To determine the correct temperature in Centigrade, divide by 2.
To determine the correct temperature in Fahrenheit, divide by 2, then multiply by 9/5 and add 32.
KarlBridges that are not equipped with the Dallas chip return a 'noSuchName' error."
```

**Classification:** MIB object for network management

### Child OIDs

No child OID

### Terms of Use

[Terms of use](https://oid-base.com/disclaimer.htm.md)

**Note to implementers:**: The OID repository is constantly updated but does not necessarily store the latest (or most accurate) version of this formal description. For an implementation, it is recommended to search the web for a more recent description. If this is the case, please update the above description.