oid: "1.3.6.1.4.1.644.2.4.2.7.1.1.1.9"
short-description: "optDevCmdStatus OBJECT-TYPE"
last-modified: "2018-01-03"
parent-oid: "1.3.6.1.4.1.644.2.4.2.7.1.1.1"
---

## OID: `1.3.6.1.4.1.644.2.4.2.7.1.1.1.9`

```asn1
{iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) 644 eriProducts(2) dnx(4) devices(2) dnxStm1Oc3(7) opticalConfig(1) opticalDevConfigTable(1) opticalDevConfigEntry(1) optDevCmdStatus(9)}
```

### Description

```asn1
optDevCmdStatus OBJECT-TYPE
SYNTAX INTEGER {
\-- Initial default status for a row
ready-for-command (0),
\-- Device Commands used in SET Command (1..99)
update-config (1),

\-- Device Response States used in GET RESPONSE Command (100..199)
update-successful (101),

\-- Device Config Error Codes used in GET RESPONSE Command (400..799)
err-general-opt-config-error (400),
err-au4Seq-cannot-be-mixed-framing (402),
err-invalid-opt-dev-command (403),
err-device-is-protection-module (414),
err-invalid-multiplex-map (415),
err-invalid-payload-framing (416),
err-invalid-xlink-nest-num (419),
err-invalid-line-timing (421),
err-ts-alloc-not-applicable (424),
err-xlink-pair-not-applicable (427),
err-data-locked-by-another-user (450),
err-snmp-parse-failed (500),
err-invalid-snmp-type (501),
err-invalid-snmp-var-size (502)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The command status for this link configuration row/record.
The value used in a SET will be replaced by a response
value in the GET RESPONSE indicating success or failure.

Default Response State used in GET RESPONSE Command
ready-for-command (0)
initial default status for a row

Stm1Oc3 Device Cfg Commands used in SET Command (1..99)
update-config(1),
Change existing Stm1Oc3 Device Configuration

Response States used in GET RESPONSE Command (100..199)
update-successful (101)
Device data has been successfully changed

Stm1Oc3 Device Config Error Codes used in GET RESPONSE Command (400..799)
err-general-opt-config-error (400)
Unknown Device configuration error occurred
err-au4Seq-cannot-be-mixed-framing (402)
Au4 sequential mode supports only all-E1 or all-T1 Payloads
err-invalid-opt-dev-command (403)
Unrecognized device command-action
err-device-is-protection-module (414)
Can't configure Device designated as Protection (odd # slot)
err-invalid-multiplex-map (415)
Configured multiplexing structure not valid for device type
err-invalid-payload-framing (416)
Unrecognized payload group type
err-invalid-xlink-nest-num (419)
X-Link cannot be assigned to selected Nest
err-invalid-line-timing (421)
Unrecognized clock setting
err-ts-alloc-not-applicable (424)
Timeslot Alloc can only be configured for STM1 or OC3
cards in Standalone DNX systems
err-xlink-pair-not-applicable (427)
X-Link assignement can only be changed for STM1X or
OC3X cards in DNX88 systems.
err-data-locked-by-another-user (450)
Another administrative user is making changes to this
part of the system via a terminal session. Check Event
Log for user name.
err-snmp-parse-failed (500)
Agent could not parse variable
err-invalid-snmp-type (501)
Variable ASN type does not match Agent defined type
err-invalid-snmp-var-size (502)
Variable size is too big"
```

**Classification:** MIB object for network management

### Child OIDs

No child OID

### Terms of Use

[Terms of use](https://oid-base.com/disclaimer.htm.md)

**Note to implementers:**: The OID repository is constantly updated but does not necessarily store the latest (or most accurate) version of this formal description. For an implementation, it is recommended to search the web for a more recent description. If this is the case, please update the above description.