oid: "1.3.6.1.4.1.644.2.4.1.9.3"
short-description: "ndrAutoSwitchover OBJECT-TYPE"
last-modified: "2018-01-03"
parent-oid: "1.3.6.1.4.1.644.2.4.1.9"
---

## OID: `1.3.6.1.4.1.644.2.4.1.9.3`

```asn1
{iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) 644 eriProducts(2) dnx(4) sysMgr(1) redundancy(9) ndrAutoSwitchover(3)}
```

### Description

```asn1
ndrAutoSwitchover OBJECT-TYPE
SYNTAX INTEGER {
manual (0),
automatic (1),
narrowband-auto (2),
broadband-1-auto (3),
broadband-2-auto (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the user's desired N+1 Device Redundancy automatic
Switchover setting when a primary card fails.

manual (0) Failed cards will not be switched automatically
by the system. User is required to go to Node
Summary Console screen and force a manual
switchover of the failed card to the Redundant.
automatic (1) The system will automatically switch out failed cards
for either NDR Group with the Redundant card.
narrowband-auto (2) The system will automatically switch out a failed card
for the NDR Narrowband Group with the Redundant.
broadband-1-auto(3) The system will automatically switch out a failed card
for the NDR Broadband Group 1 with the Redundant.
broadband-2-auto(4) The system will automatically switch out a failed card
for the NDR Broadband Group 2 with the Redundant."
```

**Classification:** MIB object for network management

### Child OIDs

No child OID

### Terms of Use

[Terms of use](https://oid-base.com/disclaimer.htm.md)

**Note to implementers:**: The OID repository is constantly updated but does not necessarily store the latest (or most accurate) version of this formal description. For an implementation, it is recommended to search the web for a more recent description. If this is the case, please update the above description.