oid: "1.3.6.1.4.1.644.2.4.1.7.2.6"
short-description: "clockSrcCmdStatus OBJECT-TYPE"
last-modified: "2025-04-09"
parent-oid: "1.3.6.1.4.1.644.2.4.1.7.2"
---

## OID: `1.3.6.1.4.1.644.2.4.1.7.2.6`

```asn1
{iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) 644 eriProducts(2) dnx(4) sysMgr(1) sysClock(7) clockSrcConfig(2) clockSrcCmdStatus(6)}
```

### Description

```asn1
clockSrcCmdStatus OBJECT-TYPE
SYNTAX INTEGER {
\-- Initial default status for a row
ready-for-command(0),
\-- Clock Source Commands used in SET Command (1..99)
update-clock-src(1),
\-- Response States used in GET RESPONSE Command (100..199)
update-successful(101),
\-- Clock Source Config Error Codes used in GET RESPONSE Command (200..799)
err-gen-clock-src-config-error(200), err-invalid-slot(201), err-invalid-port(202), err-invalid-clock-src-command(203), err-invalid-clock-mode(204), err-invalid-station-clock(205), err-data-locked-by-another-user(450), err-snmp-parse-failed(500), err-invalid-snmp-type(501), err-invalid-snmp-var-size(502)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The command status for this Clock Source configuration.
The value used in a SET will be replaced by a response
value in the GET RESPONSE indicating success or failure.
Default Response State used in GET RESPONSE Command
ready-for-command (0)
initial default status for a row
Clock Source Commands used in SET Command (1..99)
update-clock-src (1)
Change the source for primary, secondary or tertiary
clocks
Response States used in GET RESPONSE Command (100..199)
update-successful (101)
clock source data has been successfully changed
Clock Source Error Codes used in GET RESPONSE Command (200..799)
err-gen-clock-src-config-error (200)
Unknown clock src configuration error occurred.
err-invalid-slot (201)
Configured slot not in valid range
err-invalid-port (202)
Configured port not in valid range
err-invalid-clock-src-command (203,
Unrecognized clock src command action
err-invalid-clock-mode (204)
Unrecognized clock src fallback
err-invalid-station-clock (205)
Configured station not valid
err-data-locked-by-another-user (450)
Another administrative user is making changes to this
part of the system via a terminal session. Check Event
Log for user name
err-snmp-parse-failed (500)
Agent could not parse variable
err-invalid-snmp-type (501)
Variable ASN type does not match Agent defined type
err-invalid-snmp-var-size (502)
Variable size is too big"
```

**Classification:** MIB object for network management

### Child OIDs

No child OID

### Terms of Use

[Terms of use](https://oid-base.com/disclaimer.htm.md)

**Note to implementers:**: The OID repository is constantly updated but does not necessarily store the latest (or most accurate) version of this formal description. For an implementation, it is recommended to search the web for a more recent description. If this is the case, please update the above description.