oid: "1.3.6.1.4.1.2680.1.1.3.6.1"
short-description: "modeRateControl OBJECT-TYPE"
last-modified: "2021-03-04"
parent-oid: "1.3.6.1.4.1.2680.1.1.3.6"
---

## OID: `1.3.6.1.4.1.2680.1.1.3.6.1`

```asn1
{iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) 2680 cobraNet(1) coreManager(1) errors(3) modeRate(6) modeRateControl(1)}
```

### Description

```asn1
modeRateControl OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Selects latency and sample rate operating mode for the interface.
note that this variable is read-only. operating mode can only be
changed by local host through HMI.
The following modes are supported:
0x701 - 5-1/3ms latency, 96Khz sample rate
0x700 - 10-2/3ms latency, 48Khz sample rate
0x600 - 5-1/3ms latency, 48Khz sample rate
0x601 - 2-2/3ms latency, 96Khz sample rate
0x500 - 2-2/3ms latency, 48Khz sample rate
0x501 - 1-1/3ms latency, 96Khz sample rate
0x400 - 1-1/3ms latency, 48Khz sample rate
0x401 - 2/3ms latency, 96Khz sample rate
0x300 - 2/3ms latency, 48Khz sample rate
0x301 - 1/3ms latency, 96Khz sample rate
0x200 - 1/3ms latency, 48Khz sample rate
0x201 - 1/6ms latency, 96Khz sample rate"
```

**Classification:** MIB object for network management

### Child OIDs

No child OID

### Terms of Use

[Terms of use](https://oid-base.com/disclaimer.htm.md)

**Note to implementers:**: The OID repository is constantly updated but does not necessarily store the latest (or most accurate) version of this formal description. For an implementation, it is recommended to search the web for a more recent description. If this is the case, please update the above description.