oid: "1.3.6.1.4.1.232.6.2.6.8.1.5"
short-description: "cpqHeTemperatureThreshold OBJECT-TYPE"
last-modified: "2022-01-21"
parent-oid: "1.3.6.1.4.1.232.6.2.6.8.1"
---

## OID: `1.3.6.1.4.1.232.6.2.6.8.1.5`

```asn1
{iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) 232 cpqHealth(6) cpqHeComponent(2) cpqHeThermal(6) cpqHeTemperatureTable(8) cpqHeTemperatureEntry(1) cpqHeTemperatureThreshold(5)}
```

### Description

```asn1
cpqHeTemperatureThreshold OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This is the shutdown threshold temperature sensor setting
in degrees celsius. This is the temperature in which the
sensor will be considered to be in a failed state thus
causing the system to be shutdown.
If this value cannot be determined by software, then a value
of -99 will be returned.
Only the Ambient zone type allows setting of the threshold
temperature."
```

**Classification:** MIB object for network management

### Child OIDs

No child OID

### Terms of Use

[Terms of use](https://oid-base.com/disclaimer.htm.md)

**Note to implementers:**: The OID repository is constantly updated but does not necessarily store the latest (or most accurate) version of this formal description. For an implementation, it is recommended to search the web for a more recent description. If this is the case, please update the above description.