oid: "1.3.6.1.4.1.2272.1.64.1.1.3.1.9"
short-description: "rcSlppPortGuardTimeout OBJECT-TYPE"
last-modified: "2017-12-14"
parent-oid: "1.3.6.1.4.1.2272.1.64.1.1.3.1"
---

## OID: `1.3.6.1.4.1.2272.1.64.1.1.3.1.9`

```asn1
{iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) 2272 rcMgmt(1) rcSlpp(64) rcSlppMib(1) rcSlppObjects(1) rcSlppPortTable(3) rcSlppPortEntry(1) rcSlppPortGuardTimeout(9)}
```

### Description

```asn1
rcSlppPortGuardTimeout OBJECT-TYPE
SYNTAX Integer32 (0|10..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This value specifies the time period for which a port will remain
disabled. When SLPP-guard disables a port, after this time period
expires, the port will become re-enabled. A value of 0 means ports
will never be re-enabled."
```

**Classification:** MIB object for network management

### Child OIDs

No child OID

### Terms of Use

[Terms of use](https://oid-base.com/disclaimer.htm.md)

**Note to implementers:**: The OID repository is constantly updated but does not necessarily store the latest (or most accurate) version of this formal description. For an implementation, it is recommended to search the web for a more recent description. If this is the case, please update the above description.