oid: "1.3.6.1.4.1.223.10.6.17"
short-description: "uemSensorTable OBJECT-TYPE"
last-modified: "2018-02-19"
parent-oid: "1.3.6.1.4.1.223.10.6"
---

## OID: `1.3.6.1.4.1.223.10.6.17`

```asn1
{iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) 223 unisysOpen(10) unisysEnvMonitor(6) uemSensorTable(17)}
```

### Description

```asn1
uemSensorTable OBJECT-TYPE
SYNTAX SEQUENCE OF UemSensorTableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"All fan, temperature and voltage sensors are collected in this table.
All these devices are similar in that they monitor 5 value ranges:
low critical, low warning, normal, high warning, high critical.
Notifications (trap messages) are sent whenever the monitored value moves
from one value range to another. The guard points defining the 5 monitored
regions (or range of values) are read-write allowing remote configuration
by an SNMP management console.
There may be zero or more rows in this table. Each row in the table contains
information about a single sensor. One column, uemSensorType, identifies
the type of sensor as fan, temp or voltage. Another column, uemSensorStatus,
identifies where in the 5 possible ranges the monitored device is currently
operating within. Each row is linked to a parent EnvMonitor row to further
identify its location within the server."
```

**Classification:** MIB object for network management

### Child OIDs

- `1.3.6.1.4.1.223.10.6.17.1`: `uemSensorTableEntry(1)`

### Terms of Use

[Terms of use](https://oid-base.com/disclaimer.htm.md)

**Note to implementers:**: The OID repository is constantly updated but does not necessarily store the latest (or most accurate) version of this formal description. For an implementation, it is recommended to search the web for a more recent description. If this is the case, please update the above description.