oid: "1.3.6.1.4.1.2158.3.1.1.1.1.2.1"
short-description: "hneSysSyncTimingMode OBJECT-TYPE"
last-modified: "2018-06-18"
parent-oid: "1.3.6.1.4.1.2158.3.1.1.1.1.2"
---

## OID: `1.3.6.1.4.1.2158.3.1.1.1.1.2.1`

```asn1
{iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) 2158 salixProducts(3) hybridSwitch(1) hneMIB(1) hneMIBObjects(1) hneSystem(1) hneSystemSync(2) hneSysSyncTimingMode(1)}
```

### Description

```asn1
hneSysSyncTimingMode OBJECT-TYPE
SYNTAX INTEGER { internal(1), line(2), external(3) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"An identification of the source from which timing is derived by
the working sync module within the HNE. Possible values are:

internal(1) - the internal oscillator on the sync module will be
used as the master clock for system synchronization.
line(2) - the sync module is synchronizing with the receive
line timing from a signal received by an LIU.
external(3) - the Building Integrated Timing System (BITS)
available on a T1 line plugged into an LIU will be
used as the master clock for system synchronization."
DEFVAL { internal }
```

**Classification:** MIB object for network management

### Child OIDs

No child OID

### Terms of Use

[Terms of use](https://oid-base.com/disclaimer.htm.md)

**Note to implementers:**: The OID repository is constantly updated but does not necessarily store the latest (or most accurate) version of this formal description. For an implementation, it is recommended to search the web for a more recent description. If this is the case, please update the above description.