oid: "1.3.6.1.4.1.2158.2.3.1.5.9"
short-description: "salixSysSyncWorking OBJECT-TYPE"
last-modified: "2018-06-18"
parent-oid: "1.3.6.1.4.1.2158.2.3.1.5"
---

## OID: `1.3.6.1.4.1.2158.2.3.1.5.9`

```asn1
{iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) 2158 salixGeneric(2) salixSystemMIB(3) salixSystemMIBObjects(1) salixSystemSync(5) salixSysSyncWorking(9)}
```

### Description

```asn1
salixSysSyncWorking OBJECT-TYPE
SYNTAX PhysicalIndex
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The entPhysicalIndex of the sync module plug-in unit that is
providing the system synchronizaton signal. Writing a new value
to this object, a value not equal to the current value, will:

- update the salixSysSyncProtect object with the current value
of the salixSysSyncWorking object and

- activate the specified sync module to start providing the
system synchronization signal.

A value of 0 indicates that there are no operational or not
installed sync modules in the system. Writing zero, an invalid
index, or the current value to this object will have no effect.

If the working sync module fails, the system will automatically
switch to the sync module specified in the salixSysSyncProtect
object."
```

**Classification:** MIB object for network management

### Child OIDs

No child OID

### Terms of Use

[Terms of use](https://oid-base.com/disclaimer.htm.md)

**Note to implementers:**: The OID repository is constantly updated but does not necessarily store the latest (or most accurate) version of this formal description. For an implementation, it is recommended to search the web for a more recent description. If this is the case, please update the above description.