oid: "1.3.6.1.4.1.2.6.33.1.6.7"
short-description: "transferResult OBJECT-TYPE"
last-modified: "2025-07-17"
parent-oid: "1.3.6.1.4.1.2.6.33.1.6"
---

## OID: `1.3.6.1.4.1.2.6.33.1.6.7`

```asn1
{iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) 2 ibmProd(6) atmSw(33) node(1) tftp(6) transferResult(7)}
```

### Description

```asn1
transferResult OBJECT-TYPE
SYNTAX INTEGER {not-initialized(1), transfer-successful(2), upload-in-progress(3), download-in-progress(4), generic-error(5), no-response-from-host(6), connection-lost(7), file-not-found(8), file-empty(9), file-too-big(10), access-rights-violation(11), invalid-file-header(12), checksum-error(13), transfer-error(14), hardware-error(15), file-already-exists(16), config-unreadable-version(17), config-file-empty(18), config-impossible(19), config-internal-error(20), config-applied-ok(21)}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The result of the latest file transfer.
When one of the TFTP variables is modified, this
variable is reset to not-initialized.
When a configuration file is downloaded, the content of
the configuration file is checked. If the file is valid
and if a reset is mandatory then the atm subsystem is
reset automatically.
If the configuration file is not valid or if a reset
is not required, the following values are returned in
transferResult:
- config-unreadable-version: the control point
does not support the version of configuration file.
This configuration file has probably been built
by a further version of control point.
- config-file-empty: the configuration file is not valid
- config-impossible: the configuration file cannot
be applied (internal error, or file corrupted)
- config-internal-error: internal error detected while
checking the configuration file.
- config-applied-ok: the configuration file is valid
and a reset is not mandatory."
```

**Classification:** MIB object for network management

### Child OIDs

No child OID

### Terms of Use

[Terms of use](https://oid-base.com/disclaimer.htm.md)

**Note to implementers:**: The OID repository is constantly updated but does not necessarily store the latest (or most accurate) version of this formal description. For an implementation, it is recommended to search the web for a more recent description. If this is the case, please update the above description.