oid: "1.3.6.1.4.1.2.6.147.2.1.1.3.2.1.8"
short-description: "hubRdntLinkStatus OBJECT-TYPE"
last-modified: "2025-11-27"
parent-oid: "1.3.6.1.4.1.2.6.147.2.1.1.3.2.1"
---

## OID: `1.3.6.1.4.1.2.6.147.2.1.1.3.2.1.8`

```asn1
{iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) 2 ibmProd(6) ibm8245(147) fastEnetHubMgmt(2) hub110(1) hubCfgPackage(1) hubRedundantLinkCfg(3) hubRedundantLinkTable(2) hubRedundantLinkEntry(1) hubRdntLinkStatus(8)}
```

### Description

```asn1
hubRdntLinkStatus OBJECT-TYPE
SYNTAX INTEGER {enabled(1), disabled(2), suspended(3), invalid(4), return-to-primary-link(5)}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object enables/disables the operation of specific redundant link.
When sets this object to invalid(4), the entry for this redundant link
pair will be removed.
When redundant link pair enabled(1) is requested, the primary link
specified by objects hubRdntLinkPrimaryLinkGrpNum and
hubRdntLinkPrimaryLinkPortNum will be selected and enabled as
active link. The object hubRdntLinkActiveLink will be set
to primary-link(1).
When suspended(4) is requested, the active link indicated by object
hubRdntLinkActiveLink will be disabled. At this moment, both
primary link and secondary link are disabled. If user set enabled(1)
to this object then the link specified by object hubRdntLinkActiveLink
will be re-enabled again.
When disabled(3) is requested, both primary link and secondary link
will be configured based on their hubPortAdminState respectively.
Note: A loop condition could be happened if both primary link
and secondary are enabled.
When return-to-primary-link(5) is requested, a trap will be sent
to indicate port switch over event if the secondary link is active link.
The secondary link will be disabled and the primary link will be
enabled immediately.
The value of this object will automatically return to enabled(1),
and the object hubRdntLinkActiveLink will be set to primary-link(1).
Note: Once a redundant link pair is in enabled(1) or suspended(3) state,
the information configured for the redundant link can not be
changed in any condition.
To re-configure the redundant link, this object must be first
set to invalid(4) or disabled(2) state, and then re-enabled it
latter by setting this object to enabled(1)."
```

**Classification:** MIB object for network management

### Child OIDs

No child OID

### Terms of Use

[Terms of use](https://oid-base.com/disclaimer.htm.md)

**Note to implementers:**: The OID repository is constantly updated but does not necessarily store the latest (or most accurate) version of this formal description. For an implementation, it is recommended to search the web for a more recent description. If this is the case, please update the above description.