oid: "1.3.6.1.4.1.181.1.13.1.5.1"
short-description: "confConfigureUpperSupply OBJECT-TYPE"
last-modified: "2018-02-13"
parent-oid: "1.3.6.1.4.1.181.1.13.1.5"
---

## OID: `1.3.6.1.4.1.181.1.13.1.5.1`

```asn1
{iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) 181 ktxProducts(1) aac3(13) aac3ConfigGroup(1) confChassis(5) confConfigureUpperSupply(1)}
```

### Description

```asn1
confConfigureUpperSupply OBJECT-TYPE
SYNTAX INTEGER {
upperBayNotSpecified(1),
upperBayEmpty(2),
upperBayAc(3),
upperBayDc(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The configuration of the upper power supply bay. The type
of power supply installed (i.e., AC or DC) must be specified
in order for the system software to monitor the power supply
for failure. This variable reports upperBayNotSpecified if
the power supply type has never been set, in which case the
system will not monitor the supply for failure. If the
variable is set to upperBayEmpty, the power supply bay will
also not be monitored by the system."
```

**Classification:** MIB object for network management

### Child OIDs

No child OID

### Terms of Use

[Terms of use](https://oid-base.com/disclaimer.htm.md)

**Note to implementers:**: The OID repository is constantly updated but does not necessarily store the latest (or most accurate) version of this formal description. For an implementation, it is recommended to search the web for a more recent description. If this is the case, please update the above description.