oid: "1.3.6.1.4.1.164.6.5.1.10.1.2"
short-description: "alarmRelayOutputEnergized OBJECT-TYPE"
last-modified: "2024-05-03"
parent-oid: "1.3.6.1.4.1.164.6.5.1.10.1"
---

## OID: `1.3.6.1.4.1.164.6.5.1.10.1.2`

```asn1
{iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) 164 radGen(6) fmObjects(5) alarmEventConfig(1) alarmRelayOutputTable(10) alarmRelayOutputEntry(1) alarmRelayOutputEnergized(2)}
```

### Description

```asn1
alarmRelayOutputEnergized OBJECT-TYPE
SYNTAX INTEGER {no(2), yes(3)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object shows whether the relay transports electricity permanently (energized)
or just when the alarm is activated (deEnergized).
Default value for critical alarm relay on chassis will be: energized (1).
For other severities, the default is: deEnergized (2)."
```

**Classification:** MIB object for network management

### Child OIDs

No child OID

### Terms of Use

[Terms of use](https://oid-base.com/disclaimer.htm.md)

**Note to implementers:**: The OID repository is constantly updated but does not necessarily store the latest (or most accurate) version of this formal description. For an implementation, it is recommended to search the web for a more recent description. If this is the case, please update the above description.