oid: "1.3.6.1.4.1.1206.4.2.2.5.6.1.5"
short-description: "rmcTBRateCtrl OBJECT-TYPE"
last-modified: "2025-11-19"
parent-oid: "1.3.6.1.4.1.1206.4.2.2.5.6.1"
---

## OID: `1.3.6.1.4.1.1206.4.2.2.5.6.1.5`

```asn1
{iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) 1206 transportation(4) devices(2) ramp(2) rmcTimebase(5) rmcMeterActionTable(6) rmcMeterActionEntry(1) rmcTBRateCtrl(5)}
```

### Description

```asn1
rmcTBRateCtrl OBJECT-TYPE
SYNTAX INTEGER(0..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indicates the metering rate that to be used if the metered lane is commanded
by timebase control and the rmcImplementAction-object has a value of
'fixedRate'. This object is used to control the entry, while the
rmcTBRateStatus-object indicates the status.
This value shall be expressed in 1-vph increments.
A suggested usable range is 120 to 1800.
<Unit> vehicles per hour
<Object Identifier> 1.3.6.1.4.1.1206.4.2.2.5.6.1.5"
REFERENCE
"See Clause A.3.1"
```

**Classification:** MIB object for network management

### Child OIDs

No child OID

### Terms of Use

[Terms of use](https://oid-base.com/disclaimer.htm.md)

**Note to implementers:**: The OID repository is constantly updated but does not necessarily store the latest (or most accurate) version of this formal description. For an implementation, it is recommended to search the web for a more recent description. If this is the case, please update the above description.