oid: "1.3.6.1.4.1.1206.4.2.2.2.4.1.9"
short-description: "rmcMLNoActivity OBJECT-TYPE"
last-modified: "2025-11-19"
parent-oid: "1.3.6.1.4.1.1206.4.2.2.2.4.1"
---

## OID: `1.3.6.1.4.1.1206.4.2.2.2.4.1.9`

```asn1
{iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) 1206 transportation(4) devices(2) ramp(2) rmcML(2) rmcMLCtrlTable(4) rmcMLCtrlEntry(1) rmcMLNoActivity(9)}
```

### Description

```asn1
rmcMLNoActivity OBJECT-TYPE
SYNTAX INTEGER(0..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"If the input of a mainline lane detector has not been actuated for longer
than this threshold, the rmcMLLeadStatus- (or rmcMLTrailStatus-) object for
that detector shall be set to a value of 'noActivity'.
This value shall be expressed in 1-minute increments.
A suggested usable range is 0 to 1500.
A value of zero (0) shall inhibit the no activity testing.
<Unit> minute
<Object Identifier> 1.3.6.1.4.1.1206.4.2.2.2.4.1.9"
REFERENCE
"See Clause A.2.1"
DEFVAL {0}
```

**Classification:** MIB object for network management

### Child OIDs

No child OID

### Terms of Use

[Terms of use](https://oid-base.com/disclaimer.htm.md)

**Note to implementers:**: The OID repository is constantly updated but does not necessarily store the latest (or most accurate) version of this formal description. For an implementation, it is recommended to search the web for a more recent description. If this is the case, please update the above description.