oid: "1.3.6.1.4.1.1206.4.1.1.7.9.7.1.3"
short-description: "recConfigMode OBJECT-TYPE"
last-modified: "2025-07-23"
parent-oid: "1.3.6.1.4.1.1206.4.1.1.7.9.7.1"
---

## OID: `1.3.6.1.4.1.1206.4.1.1.7.9.7.1.3`

```asn1
{iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) 1206 transportation(4) protocols(1) layers(1) application(7) recMech(9) recConfigTable(7) recConfigEntry(1) recConfigMode(3)}
```

### Description

```asn1
recConfigMode OBJECT-TYPE
SYNTAX INTEGER {other(1), onChange(2), greaterThanValue(3), smallerThanValue(4), hysteresisBound(5), periodic(6), andedWithValue(7)}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"<Definition>This object specifies the mode of operation for
this recording. The modes are defined as follows:
Value Description
other the recording mode of operation is not
described in this standard, refer to the
device manual.
onChange trigger a recording when the object value
referenced by recConfigCompareOID
changes. The values of
recConfigCompareValue and
recConfigCompareValue2 are ignored in
this mode.
greaterThanValue trigger a recording when the object value
referenced by recConfigCompareOID
becomes greater than the value of
recConfigCompareValue for the time
(tenth seconds) defined by
recConfigCompareValue2 (zero means
immediate logging).
smallerThanValue trigger a recording when the object value
referenced by recConfigCompareOID
becomes less than the value of
recConfigCompareValue for the time
(tenth seconds) defined by
recConfigCompareValue2 (zero means
immediate logging).
hysteresisBound trigger a recording when the object value
referenced by recConfigCompareOID
becomes less than or greater than the
bound values. The lowerbound value is the
lower value of recConfigCompareValue and
recConfigCompareValue2; the upperbound
value is the higher value of the two values.
When the object value becomes greater than
the upper bound value, subsequent triggering of
upperbound conditions shall not occur until
the object value becomes less than the
lower bound value.
When the object value becomes less than
the lower bound value, subsequent triggering
of lowerbound conditions shall not occur
until the object value becomes greater
than the upper bound value.
periodic trigger a recording every x seconds, where
x is defined by the value stored in
recConfigCompareValue. The values stored
in recConfigCompareValue2 and
recConfigCompareOID are ignored in this
mode.
andedWithValue trigger a recording when the object value
referenced by recConfigCompareOID ANDED
with the value of recConfigCompareValue
is NOT equal to zero for the time (tenth
seconds) defined by recConfigCompareValue2
(zero means immediate logging). This allows
monitoring of a specific bit; the condition
becomes true anytime that any one of the
selected bits become true.
<Object Identifier> 1.3.6.1.4.1.1206.4.1.1.7.97.1.3"
DEFVAL {onChange}
```

**Classification:** MIB object for network management

### Child OIDs

No child OID

### Terms of Use

[Terms of use](https://oid-base.com/disclaimer.htm.md)

**Note to implementers:**: The OID repository is constantly updated but does not necessarily store the latest (or most accurate) version of this formal description. For an implementation, it is recommended to search the web for a more recent description. If this is the case, please update the above description.