oid: "1.3.6.1.2.1.54.1.2.7"
short-description: "sysApplPastRunTblTimeLimit OBJECT-TYPE"
last-modified: "2020-07-01"
parent-oid: "1.3.6.1.2.1.54.1.2"
---

## OID: `1.3.6.1.2.1.54.1.2.7`

```asn1
{iso(1) identified-organization(3) dod(6) internet(1) mgmt(2) mib-2(1) sysApplMIB(54) sysApplOBJ(1) sysApplRun(2) sysApplPastRunTblTimeLimit(7)}
```

### Description

```asn1
sysApplPastRunTblTimeLimit OBJECT-TYPE
SYNTAX Unsigned32 (0..'ffffffff'h)
UNITS "seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum time in seconds which an entry in the
sysApplPastRunTable may exist before it is removed.
Any entry that is older than this value will be
removed (aged out) from the table.
Note that an entry may be aged out prior to reaching
this time limit if it is the oldest entry in the
table and must be removed to make space for a new
entry so as to not exceed sysApplPastRunMaxRows."
DEFVAL {7200}
```

**Classification:** MIB object for network management

### Supplementary information

Automatically extracted from IETF [RFC 2287](https://www.rfc-editor.org/rfc/rfc2287.html).

### Child OIDs

No child OID

### Terms of Use

[Terms of use](https://oid-base.com/disclaimer.htm.md)

**Note to implementers:**: The OID repository is constantly updated but does not necessarily store the latest (or most accurate) version of this formal description. For an implementation, it is recommended to search the web for a more recent description. If this is the case, please update the above description.