oid: "1.3.6.1.2.1.22.2.1.1"
short-description: "rptrMonitorTransmitCollisions OBJECT-TYPE"
last-modified: "2020-06-23"
parent-oid: "1.3.6.1.2.1.22.2.1"
---

## OID: `1.3.6.1.2.1.22.2.1.1`

```asn1
{iso(1) identified-organization(3) dod(6) internet(1) mgmt(2) mib-2(1) snmpDot3RptrMgt(22) rptrMonitorPackage(2) rptrMonitorRptrInfo(1) rptrMonitorTransmitCollisions(1)}
```

### Description

```asn1
rptrMonitorTransmitCollisions OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"********* THIS OBJECT IS DEPRECATED **********
For a clause 9 (10Mb/s) repeater, this counter
is incremented every time the repeater state
machine enters the TRANSMIT COLLISION state
from any state other than ONE PORT LEFT
(Ref: Fig 9-2 [IEEE 802.3 Std]).
For a clause 27 repeater, this counter is
incremented every time the repeater core state
diagram enters the Jam state as a result of
Activity(ALL) > 1 (fig 27-2 [IEEE 802.3 Std]).
The approximate minimum time for rollover of this
counter is 16 hours in a 10Mb/s repeater and 1.6
hours in a 100Mb/s repeater."
REFERENCE
"[IEEE 802.3 Mgt], 30.4.1.1.8, aTransmitCollisions."
```

**Classification:** Deprecated or obsolete OID; MIB object for network management

### Supplementary information

Automatically extracted from IETF [RFC 2108](https://www.rfc-editor.org/rfc/rfc2108.html)

### Child OIDs

No child OID

### Terms of Use

[Terms of use](https://oid-base.com/disclaimer.htm.md)

**Note to implementers:**: The OID repository is constantly updated but does not necessarily store the latest (or most accurate) version of this formal description. For an implementation, it is recommended to search the web for a more recent description. If this is the case, please update the above description.